Fuzzy Media Storage
NEXUS-fms provides an effective and expandable storage solution ranging from 2 to 512 terabytes. Unique to the NEXUS-fms solution is the concept to use uncomplicated hardware to implement redundant storage. Performance, storage capacity and management is distributed over a cluster of 1U NEXUS-fms servers implementing a truly scalable storage solution. The native integration with other PubliTronic products allows for a single supplier solution resulting in a fast and effortless implementation of your playout requirements.
|
|

(Click to enlarge)
|
|
Key Features
|
|
Concept
Bigger and faster storage solutions tend to get more vulnerable to errors due to the addition of complex hardware.
PubliTronic have solved this by implementing a forward error correction (FEC) technique in the NEXUS-fms servers utilizing distributed processor performance on the servers as a powerful alternative for hardware RAID solutions.
The FEC scheme is configurable and as such the customer defines the desired redundancy. Typically a 4/5 scheme is chosen resulting in
|
|
80% efficiency of the raw storage. For example; 5x NEXUS-fms 1U servers of 2TB result in a total effective storage of 8TB. The 4/5 scheme uses 20 % redundancy, meaning 1 NEXUS-fms server can fail without compromising the NEXUS-fms cluster functionality.

(Click to enlarge)
|
For more information on our products, please contact your local distributor or mail to sales@publitronic.com.
|
| Technical Details |
| Storage capacity |
2 terabytes - per 1U frame |
| Data throughput |
400 Mb/sec. - per 1U server |
| FEC schemes |
configurable: 1/2, 2/3, 3/4 |
| Transfer protocols |
FTP, SMB (windows share) |
| Discs |
SATA II, swappable |
| CPU |
Intel Xeon |
| Memory |
4 Gb |
| Linux OS |
Real-time 2.6 |
| Ethernet |
2 x: 10/100/1G |
| PC i/f |
VGA, keyb, RS232 |
| Size (W x H x D) |
484 x 44 x 600 mm - 19” x 1,74” x 23,6” |
| Weight |
max. 15 kg / max. 33 lbs |
| PSU |
Redundant, dual AC, max. 500 VA |
| Operating environment |
10˚C to 30˚C / 32˚F to 86˚F |
| Relative humidity |
10% to 90% non-condensing |
|
|
|
|
|
|
|